Skip to main content
(844) 422-7000

Elvaco M-Bus Metering Gateway CMe3100

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Elvaco Equipment: M-Bus Metering Gateway CMe3100 Vulnerabilities: Missing Authentication for Critical Function, Unrestricted Upload of File with Dangerous Type, Improper Neutralization of Inpu…

Mitsubishi Electric CNC Series

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: CNC Series Vulnerability: Improper Validation of Specified Quantity in Input 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote att…

Siemens Siveillance Video Camera

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Serv…

Schneider Electric Data Center Expert

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Data Center Expert Vulnerability: Improper Verification of Cryptographic Signature, Missing Authentication for Critical Function 2. RISK EVALUATION Successful exp…

Siemens Sentron Powercenter 1000

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Serv…

Rockwell Automation Verve Asset Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: Verve Asset Manager Vulnerability: Placement of User into Incorrect Group 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unautho…

Rockwell Automation ControlLogix

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: ControlLogix Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to send a speciall…

Schneider Electric Zelio Soft 2

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Zelio Soft 2 Vulnerabilities: Use After Free, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacke…

Siemens RUGGEDCOM APE1808

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Serv…

Siemens JT2Go

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Serv…