Skip to main content
(844) 422-7000

HID Global Reader Configuration Cards

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 5.3
ATTENTION: Low attack complexity
Vendor: HID Global
Equipment: Reader Configuration Cards
Vulnerability: Improper Authorization

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to read the credential and device administration keys from a configuration card. Those keys could be used to create malicious configuration cards or credentials.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following HID products are affected:

HID iCLASS SE reader configuration cards: All versions
OMNIKEY Secure Elements reader configuration cards: All versions

3.2 Vulnerability Overview

3.2.1 IMPROPER AUTHORIZATION CWE-285

Sensitive data can be extracted from HID iCLASS SE reader configuration cards. This could include credential and device administrator keys.

CVE-2024-23806 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Multiple
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

HID Global reported this vulnerability to CISA.

4. MITIGATIONS

HID Global recommends the following mitigations to reduce the risk:

Elite Key and Custom Key customers that have kept their configuration cards secure should continue to be vigilant and restrict access to those cards. To exploit this vulnerability, a reader must be physically close to or in possession of the configuration cards to communicate with the card and extract information.

Administrators should plan to securely destroy unneeded configuration cards.

Customers using the HID standard key, and other customers who are concerned their keys may be compromised should consider steps to update the readers and credentials with new keys. To assist in this effort, HID will be introducing a free upgrade to the Elite Key program. Contact your HID representative for more information at https://www.hidglobal.com/support.

HID has also provided additional steps users can take steps to harden their readers to prevent malicious configuration changes.

iCLASS SE Readers

iCLASS SE Readers using firmware version 8.6.0.4 or higher can use the HID Reader Manager application to prevent the readers from accepting configuration changes from Configuration Cards.
If you need assistance, or if the reader firmware has not been updated to 8.6.0.4 or higher, contact HID Technical Support.

HID OMNIKEY Readers, OMNIKEY Secure Elements, iCLASS SE Reader Modules, iCLASS SE Processors

Contact HID to receive a “Shield Card” that will prevent further configuration changes using reader configuration cards.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

February 6, 2024: Initial Publication

HID Global Encoders

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 5.9
ATTENTION: Exploitable locally
Vendor: HID Global
Equipment: iCLASS SE, OMNIKEY
Vulnerability: Improper Authorization

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to read data from reader configuration cards and credentials. Reader configuration cards contain credential and device administration keys which could be used to create malicious configuration cards or credentials.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following HID products are affected when configured as an encoder:

iCLASS SE CP1000 Encoder: All versions
iCLASS SE Readers: All versions
iCLASS SE Reader Modules: All versions
iCLASS SE Processors: All versions
OMNIKEY 5427CK Readers: All versions
OMNIKEY 5127CK Readers: All versions
OMNIKEY 5023 Readers: All versions
OMNIKEY 5027 Readers: All versions

3.2 Vulnerability Overview

3.2.1 IMPROPER AUTHORIZATION CWE-285

Certain configuration available in the communication channel for encoders could expose sensitive data when reader configuration cards are programmed. This data could include credential and device administration keys.

CVE-2024-22388 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.9 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Multiple
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

HID Global reported this vulnerability to CISA.

4. MITIGATIONS

HID advises users to take the following steps to mitigate these threats.

Protect your reader configuration cards.

A malicious encoder or reader must be physically close to the reader configuration cards to communicate with them and extract information. Elite Key and Custom Key users that have kept their configuration cards secure should continue to be vigilant and restrict access to those cards.
HID standard key users and other users who are concerned their keys may be compromised should consider steps to update the readers and credentials with new keys. To assist in this effort, HID will be introducing a free upgrade to the Elite Key program. Contact your HID representative for more information.

Protect your credentials and disable legacy technologies.

Reading the PACS data from a credential is not enough to clone the credential for modern technologies like Seos and DESFire. These technologies use a credential key for authentication. However, if a system’s readers still support legacy technologies (i.e., HID Prox, MiFARE Classic, etc.), then it may be possible to insert the credential information into a legacy technology credential that would be accepted by those readers. Users are encouraged to disable legacy credential technologies in their readers.
Further, physical credentials should always be kept safe by their users, and site managers should remind their users to be vigilant with their credentials and report missing or stolen cards.

Harden your iCLASS SE Readers from configuration changes

iCLASS SE Readers using firmware firmware version 8.6.04 or higher can use the HID Reader Manager application to prevent the readers from accepting configuration changes from configuration cards. After this is complete, users may then securely destroy their reader configuration cards.
If you need assistance, or if the reader firmware has not been updated to 8.6.04 or higher, contact HID Technical Support.

Harden your HID OMNIKEY Readers, HID iCLASS SE Reader Modules, HID iCLASS SE Processors from configuration changes

Contact HID to receive a “Shield Card” that will prevent further configuration changes using reader configuration cards. After this is complete, users may then securely destroy their reader configuration cards.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely. This vulnerability has a high attack complexity.

5. UPDATE HISTORY

February 6, 2024: Initial Publication

AVEVA Edge products (formerly known as InduSoft Web Studio)

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 7.3
ATTENTION: Low attack complexity
Vendor: AVEVA
Equipment: AVEVA Edge products (formerly known as InduSoft Web Studio)
Vulnerability: Uncontrolled Search Path Element

2. RISK EVALUATION

Successful exploitation of this vulnerability could result in an attacker achieving arbitrary code execution and privilege escalation by tricking AVEVA Edge to load an unsafe DLL.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following AVEVA Edge products (formerly known as InduSoft Web Studio) are affected:

AVEVA Edge: 2020 R2 SP2 and prior

3.2 Vulnerability Overview

3.2.1 UNCONTROLLED SEARCH PATH ELEMENT CWE-427

The vulnerability, if exploited, could allow a malicious entity with access to the file system to achieve arbitrary code execution and privilege escalation by tricking AVEVA Edge to load an unsafe DLL.

CVE-2023-6132 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Multiple
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Ting Chen of UESTC discovered and disclosed this vulnerability to AVEVA. ADLab of Venustech discovered and disclosed this vulnerability to AVEVA.

4. MITIGATIONS

AVEVA recommends users upgrade to AVEVA Edge 2023, or AVEVA Edge 2020 R2 SP2 P01 as soon as possible. Upgrades can be downloaded from the AVEVA official website: AVEVA Edge 2023AVEVA Edge 2020 R2 SP2 P01.

Note: Log-in is required.

For additional information, please refer to AVEVA’s security advisory AVEVA-2024-002.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability is not exploitable remotely.

5. UPDATE HISTORY

February 1, 2024: Initial Publication

Gessler GmbH WEB-MASTER

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 9.8
ATTENTION: Exploitable Remotely/Low attack complexity
Vendor: Gessler GmbH
Equipment: WEB-MASTER
Vulnerabilities: Use of Weak Credentials, Use of Weak Hash

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow a user to take control of the web management of the device. An attacker with access to the device could also extract and break the password hashes for all users stored on the device.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Gessler GmbH WEB-MASTER, an emergency lighting management system, are affected:

WEB-MASTER: version 7.9

3.2 Vulnerability Overview

3.2.1 USE OF WEAK CREDENTIALS CWE-1391

Gessler GmbH WEB-MASTER has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device.

CVE-2024-1039 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.2.2 USE OF WEAK HASH CWE-328

Gessler GmbH WEB-MASTER user account is stored using a weak hashing algorithm. The attacker can restore the passwords by breaking the hashes stored on the device.

CVE-2024-1040 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Multiple
COUNTRIES/AREAS DEPLOYED: Worlwide
COMPANY HEADQUARTERS LOCATION: Germany

3.4 RESEARCHER

Felix Eberstaller and Nino Fürthauer of Limes Security reported these vulnerabilities to CISA.

4. MITIGATIONS

Gessler GmbH recommends updating EZ2 to 3.2 or greater and WebMaster to 4.4 or greater to mitigate these vulnerabilities. Updates have to be applied by Gessler GmbH technicians. For more information contact Gessler GmbH.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

February 1, 2024: Initial Publication

Rockwell Automation FactoryTalk Service Platform

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 9.8
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Rockwell Automation
Equipment: FactoryTalk Service Platform
Vulnerability: Improper Verification of Cryptographic Signature

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to retrieve user information and modify settings without any authentication.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Smart Security Manager, a software management platform, are affected:

FactoryTalk Service Platform: Versions prior to v6.4

3.2 Vulnerability Overview

3.2.1 IMPROPER VERIFICATION OF CRYPTOGRAPHIC SIGNATURE CWE-347

A vulnerability exists in the affected product that allows a malicious user to obtain the service token and use it for authentication on another FTSP directory. This is due to the lack of digital signing between the FTSP service token and directory. If exploited, a malicious user could potentially retrieve user information and modify settings without any authentication.

CVE-2024-21917 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported this vulnerability to CISA.

4. MITIGATIONS

Rockwell recommends the following:

Set DCOM authentication level to 6, which enables encryption of the service token and communication channel between the server and client. Please refer to Mitigating Microsoft DCOM Hardening Patch (CVE-2021-26414) for Affected Rockwell Automation Products (custhelp.com)
When it is not possible to update to v6.40 or later, enable verification of the publisher information (i.e., digital signature) of any executable attempting to use the FactoryTalk Services APIs. This helps prevent a malicious user from calling the API to receive the service token. This setting can be changed from the Application Authorization node located within System Policies using the FactoryTalk® Administration Console application.
Security Best Practices

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA also recommends users take the following measures to protect themselves from social engineering attacks:

Do not click web links or open attachments in unsolicited email messages.
Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams.
Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

January 30, 2024: Initial Publication

Mitsubishi Electric MELSEC WS Series Ethernet Interface Module

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 5.9
ATTENTION: Exploitable remotely
Vendor: Mitsubishi Electric
Equipment: MELSEC WS Series
Vulnerability: Authentication Bypass by Capture-replay

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an unauthorized attacker to login to the modules and disclose or tamper with the programs and parameters in the modules.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Mitsubishi Electric MELSEC WS Series Ethernet Interface Modules, are affected:

WS0-GETH00200: All serial numbers

3.2 Vulnerability Overview

3.2.1 AUTHENTICATION BYPASS BY CAPTURE-REPLAY CWE-294

An authentication bypass vulnerability exists in the MELSEC WS Series Ethernet Interface Modules. A remote unauthenticated attacker can bypass authentication by capture-replay attack and login to the modules. As a result, the remote attacker who has logged in may be able to disclose or tamper with the programs and parameters in the modules.

CVE-2023-6374 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.9 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Japan

3.4 RESEARCHER

Mitsubishi Electric reported this vulnerability to CISA.

4. MITIGATIONS

Mitsubishi Electric recommends that users take the following mitigation measures to minimize the risk of exploiting this vulnerability:

Use a virtual private network (VPN), etc. to encrypt the communication between affected products and the peer.
Use a firewall or virtual private network (VPN), etc. to prevent unauthorized access when Internet access is required.
Use within a LAN and block access from untrusted networks and hosts through firewalls.
Restrict physical access to affected products and to personal computers and network devices located in the LAN to which the affected products are connected.

For more information, see Mitsubishi Electric’s security advisory.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.

5. UPDATE HISTORY

January 30, 2024: Initial Publication

Rockwell Automation ControlLogix and GuardLogix

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 8.6
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Rockwell Automation
Equipment: ControlLogix, GuardLogix
Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer

2. RISK EVALUATION

Successful exploitation of this vulnerability could allow an attacker to crash the device by exploiting a Denial-of-Service (DoS) vulnerability.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Rockwell Automation ControlLogix and GuardLogix programmable logic controllers are affected:

ControlLogix 5570: Firmware version 20.011
ControlLogix 5570 redundant: Firmware versions 20.054_kit1
GuardLogix 5570: Firmware version 20.011

3.2 Vulnerability Overview

3.2.1 IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119

A Denial-of-Service (DoS) vulnerability exists that, if exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.

CVE-2024 21916 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported this vulnerability to CISA.

4. MITIGATIONS

Rockwell Automation users with the affected software are encouraged to apply the risk mitigations, if possible. Additionally, Rockwell Automation encourages users to implement their suggested security best practices to minimize the risk of vulnerability.

ControlLogix 5570: Corrected in v33.016, 34.013, 35.012, 36.011 and later
ControlLogix 5570 redundant: Corrected in v33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and later
GuardLogix 5570: Corrected in v33.016, 34.013, 35.012, 36.011 and later

For more information, see Rockwell Automation’s security advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.

5. UPDATE HISTORY

January 30, 2024: Initial Publication

Mitsubishi Electric FA Engineering Software Products

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 9.8
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Mitsubishi Electric
Equipment: EZSocket, FR Configurator2, GT Designer3 Version1(GOT1000), GT Designer3 Version1(GOT2000), GX Works2, GX Works3, MELSOFT Navigator, MT Works2, MX Component, MX OPC Server DA/UA (Software packaged with MC Works64)
Vulnerabilities: Missing Authentication for Critical Function, Unsafe Reflection

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to disclose, tamper with, destroy or delete information in the products, or cause a denial-of-service (DoS) condition on the products.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Mitsubishi Electric FA Engineering Software Products, are affected:

EZSocket: Versions 3.0 and later
FR Configurator2: All versions
GT Designer3 Version1(GOT1000): All versions
GT Designer3 Version1(GOT2000): All versions
GX Works2: Versions 1.11M and later
GX Works3: All versions
MELSOFT Navigator: Versions 1.04E and later
MT Works2: All versions
MX Component: Versions 4.00A and later
MX OPC Server DA/UA (Software packaged with MC Works64): All versions

3.2 Vulnerability Overview

3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306

A remote unauthenticated attacker may be able to bypass authentication by sending specially crafted packets and connect to the products.

CVE-2023-6942 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N).

3.2.2 USE OF EXTERNALLY-CONTROLLED INPUT TO SELECT CLASSES OR CODE (‘UNSAFE REFLECTION’) CWE-470

An attacker may be able to execute a malicious code by remotely calling a function with a path to a malicious library while connected to the products. As a result, unauthorized users may disclose, tamper with, destroy or delete information in the products, or cause a denial-of-service (DoS) condition on the products.

CVE-2023-6943 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: Japan

3.4 RESEARCHER

Reid Wightman of Dragos reported these vulnerabilities to Mitsubishi Electric.

4. MITIGATIONS

Mitsubishi Electric recommends users take the following mitigation measures to minimize the risk of exploiting these vulnerabilities:

When connecting your personal computer with the affected products to the internet, use a firewall, virtual private network (VPN), etc., to prevent unauthorized access and allow only trusted users to remote login.
Use your personal computer with the affected products within a LAN and block access from untrusted networks and hosts.
Restrict physical access to your computer using the affected products as well as to the personal computers and network devices that can communicate with it.
Install antivirus software on your personal computer using the affected products and on the personal computers that can communicate with it.
Don’t open untrusted files or click untrusted links.

For more information, see Mitsubishi Electric’s security advisory.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

January 30, 2024: Initial Publication

Rockwell Automation LP30/40/50 and BM40 Operator Interface

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 8.8
ATTENTION: Exploitable remotely/low attack complexity
Vendor: Rockwell Automation
Equipment: LP30, LP40, LP50, and BM40 Operator Panels
Vulnerability: Improper Validation of Consistency within Input, Out-of-bounds Write, Stack-based Buffer Overflow, Untrusted Pointer Dereference

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an authenticated attacker to use specifically crafted communication requests to perform a denial-of-service condition, memory overwriting, or remote code execution.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following Rockwell Automation products are affected:

LP30 Operator Panel: Versions prior to V3.5.19.0
LP40 Operator Pane: Versions prior to V3.5.19.0
LP50 Operator Panel: Versions prior to V3.5.19.0
BM40 Operator Panel: Versions prior to V3.5.19.0

3.2 Vulnerability Overview

3.2.1 IMPROPER VALIDATION OF CONSISTENCY WITHIN INPUT CWE-1288

After successful authentication, specifically crafted communication requests with inconsistent content can cause the CmpFiletransfer component to read internally from an invalid address, potentially leading to a denial-of-service condition.

CVE-2022-47378 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.2 OUT-OF-BOUNDS WRITE CWE-787

After successful authentication, specifically crafted communication requests can cause the CmpApp component to write threat actor-controlled data to memory, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47379 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H ).

3.2.3 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpApp component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47380 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.4 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpApp component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47381 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.5 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpTraceMgr component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47382 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.6 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpTraceMgr component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47383 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.7 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpTraceMgr component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47384 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.8 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpTraceMgr component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47386 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.9 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpTraceMgr component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47387 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.10 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpTraceMgr component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47388 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.11 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpTraceMgr component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47389 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.12 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpTraceMgr component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47390 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.13 STACK-BASED BUFFER OVERFLOW CWE-121

After successful authentication, specifically crafted communication requests can cause the CmpAppForce component to write threat actor-controlled data to stack, which can lead to a denial-of-service condition, memory overwriting, or remote code execution.

CVE-2022-47385 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).

3.2.14 IMPROPER VALIDATION OF CONSISTENCY WITHIN INPUT CWE-1288

After successful authentication, specifically crafted communication requests with inconsistent content can cause the CmpApp/CmpAppBP/CmpAppForce components to read internally from an invalid address, potentially leading to a denial-of-service condition.

CVE-2022-47392 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.2.15 UNTRUSTED POINTER DEREFERENCE CWE-822

After successful authentication, specifically crafted communication requests can cause the cmpFiletransfer component to dereference addresses provided by the request for internal read access, which can lead to a denial-of-service situation.

CVE-2022-47393 has been assigned to this vulnerability. A CVSS v3.1 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: United States

3.4 RESEARCHER

Rockwell Automation reported these vulnerabilities to CISA.

4. MITIGATIONS

Rockwell Automation recommend users using the affected software to apply the risk mitigations, if possible:

Upgrade to CODESYS version 3.5.19.2 which has been released to mitigate these issues.
Additionally, we encourage the user to implement our suggested security best practices to minimize risk of the vulnerability.

Users can use Stakeholder-Specific Vulnerability Categorization to generate more environment-specific prioritization.

Additional information can be found in the CODESYS Advisory.

CISA recommends users take defensive measures to minimize the risk of exploitation of this these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

No known public exploitation specifically targeting this these vulnerabilities has been reported to CISA at this time.

5. UPDATE HISTORY

January 30, 2024: Initial Publication

Hitron Systems Security Camera DVR

View CSAF

1. EXECUTIVE SUMMARY

CVSS v3 8.1
ATTENTION: Exploitable remotely/low attack complexity/public exploits are available/known public exploitation
Vendor: Hitron Systems
Equipment: DVR
Vulnerability: Improper Input Validation

2. RISK EVALUATION

Successful exploitation of these vulnerabilities could allow an attacker to affect the availability of the product through exploitation of an improper input validation vulnerability and default credentials.

3. TECHNICAL DETAILS

3.1 AFFECTED PRODUCTS

The following versions of Hitron Systems DVR, a digital video recorder, are affected:

DVR HVR-4781: Versions 1.03 through 4.02
DVR HVR-8781: Versions 1.03 through 4.02
DVR HVR-16781: Versions 1.03 through 4.02
DVR LGUVR-4H: Versions 1.02 through 4.02
DVR LGUVR-8H: Versions 1.02 through 4.02
DVR LGUVR-16H: Versions 1.02 through 4.02

3.2 Vulnerability Overview

3.2.1 IMPROPER INPUT VALIDATION CWE-20

An improper input validation vulnerability exists in Hitron Systems DVR HVR-4781 versions 1.03 through 4.02 that could allow an attacker to cause a denial-of-service condition when using default admin name and password.

CVE-2024-22768 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.2.2 IMPROPER INPUT VALIDATION CWE-20

An improper input validation vulnerability exists in Hitron Systems DVR HVR-8781 versions 1.03 through 4.02 that could allow an attacker to cause a denial-of-service condition when using default admin name and password.

CVE-2024-22769 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.2.3 IMPROPER INPUT VALIDATION CWE-20

An improper input validation vulnerability exists in Hitron Systems DVR HVR-16781 versions 1.03 through 4.02 that could allow an attacker to cause a denial-of-service condition when using default admin name and password.

CVE-2024-22770 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.2.4 IMPROPER INPUT VALIDATION CWE-20

An improper input validation vulnerability exists in Hitron Systems DVR LGUVR-4H versions 1.02 through 4.02 that could allow an attacker to cause a denial-of-service condition when using default admin name and password.

CVE-2024-22771 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.2.5 IMPROPER INPUT VALIDATION CWE-20

An improper input validation vulnerability exists in Hitron Systems DVR LGUVR-8H versions 1.02 through 4.02 that could allow an attacker to cause a denial-of-service condition when using default admin name and password.

CVE-2024-22772 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.2.6 IMPROPER INPUT VALIDATION CWE-20

An improper input validation vulnerability exists in Hitron Systems DVR LGUVR-16H versions 1.02 through 4.02 that could allow an attacker to cause a denial-of-service condition when using default admin name and password.

CVE-2024-23842 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.4 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H).

3.3 BACKGROUND

CRITICAL INFRASTRUCTURE SECTORS: Commercial Facilities
COUNTRIES/AREAS DEPLOYED: Worldwide
COMPANY HEADQUARTERS LOCATION: South Korea

3.4 RESEARCHER

Aline Eliovich, Chad Seaman, and Larry Cashdollar of Akamai Technologies reported this vulnerability to CISA.

4. MITIGATIONS

Hitron Systems has released the following updates for their DVR:

DVR HVR-4781: Version 4.03
DVR HVR-8781: Version 4.03
DVR HVR-16781: Version 4.03
DVR LGUVR-4H: Version 4.03
DVR LGUVR-8H: Version 4.03
DVR LGUVR-16H: Version 4.03

CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities, such as:

Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet.
Locate control system networks and remote devices behind firewalls and isolating them from business networks.
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.

CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.

CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.

CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets.

Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies.

Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.

CISA has received reports of this vulnerability being actively exploited.

5. UPDATE HISTORY

January 30, 2024: Initial Publication