Schneider Electric EcoStruxure Machine SCADA Expert & Pro-face BLUE Open Studio

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.3 ATTENTION: Low Attack Complexity Vendor: Schneider Electric Equipment: EcoStruxure Machine SCADA Expert & Pro-face BLUE Open Studio Vulnerability: Use of a Broken or Risky Cryptographic Algorithm 2. RISK EVALUATION Successful exploitation of this vul…

METZ CONNECT EWIO2

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: METZ CONNECT Equipment: EWIO2 Vulnerabilities: Authentication Bypass by Primary Weakness, Improper Control of Filename for Include/Require Statement in PHP Program (‘PHP Remote File Incl…

Rockwell Automation Verve Asset Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: Verve Asset Manager Vulnerability: Incorrect Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker accessing…

Rockwell Automation FactoryTalk Policy Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Policy Manager Vulnerability: Improper Resource Shutdown or Release 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to re…

Siemens Altair Grid Engine

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Serv…

Siemens Software Center and Solid Edge

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Serv…

General Industrial Controls Lynx+ Gateway

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: General Industrial Controls Equipment: Lynx+ Gateway Vulnerabilities: Weak Password Requirements, Missing Authentication for Critical Function, Cleartext Transmission of Sensitive Information …

Mitsubishi Electric MELSEC iQ-F Series

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: MELSEC iQ-F Series Vulnerability: Improper Validation of Specified Quantity in Input 2. RISK EVALUATION Successful exploitation of this vulnerability could allow…

AVEVA Edge

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.3 ATTENTION: Low attack complexity Vendor: AVEVA Equipment: Edge Vulnerability: Use of a Broken or Risky Cryptographic Algorithm 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker to reverse engineer passwords thr…

AVEVA Application Server IDE

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.2 ATTENTION: Low attack complexity Vendor: AVEVA Equipment: Application Server IDE Vulnerability: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an …