Siemens User Management Component

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens’ ProductCERT Security Advisories (CERT Services | Services | …

Tibbo AggreGate Network Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Tibbo Equipment: AggreGate Network Manager Vulnerability: Unrestricted Upload of File with Dangerous Type 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attack…

Schneider Electric Accutech Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Accutech Manager Vulnerability: Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation could allow an attacker to cause a crash of the Accutech Manage…

Schneider Electric Modicon Controllers

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon Controllers Vulnerability: Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a victim…

Beckhoff Automation TwinCAT Package Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low Attack Complexity Vendor: Beckhoff Automation Equipment: TwinCAT Package Manager Vulnerability: Improper Neutralization of Special Elements used in an OS Command (‘OS Command Injection’) 2. RISK EVALUATION Successful exploitati…

Bosch Rexroth IndraDrive

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Bosch Rexroth Equipment: IndraDrive Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-…

Delta Electronics DIAScreen

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: DIAScreen Vulnerabilities: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this these vulnerabilities could crash the device being accessed; a buffer overflow…

Rockwell Automation FactoryTalk ThinManager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk ThinManager Vulnerabilities: Missing Authentication For Critical Function, Out-of-Bounds Read 2. RISK EVALUATION Successful exploitation of these vul…

Delta Electronics InfraSuite Device Master

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Delta Electronics Equipment: InfraSuite Device Master Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthent…

Siemens InterMesh Subscriber Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens’ ProductCERT Security Advisories (CERT Services | Serv…